Functions
Throttle adjustment
(Preparation)
- In the state in which the throttle side is selected, select the ad-
justment screen by pressing the (SEL) button.
1 (Throttle neutral 5:5 adjustment)
Confirm that the cursor is pointing to the "NEUT5:5". Set
the neutral adjuster, which is located to the left of the
stick, to the upper side (5:5). Slightly tilt and release the
throttle stick, and then press the (SEL) button while
keeping away from the stick. If the neutral adjuster is not
properly positioned, the cursor does not move to the next
step.
2 (Throttle neutral 7:3 adjustment)
Confirm that the cursor is pointing to the "NEUT7:3". Set
the neutral adjuster, which is located to the left of the
stick, to the lower side (7:3). Slightly tilt and release the
throttle stick, and then press the (SEL) button while
keeping away from the stick. If the neutral adjuster is not
properly positioned, the cursor does not move to the next
step.
3 (Throttle throw adjustment)
In the throw setup screen (figure at the right) state, lightly
operate the stick fully to the brake side and forward side
and press the (SEL) button.
4 (Correction execution)
At the check screen (figure at the right), check if neutral
is near "0%" and the brake side and forward side throw
are near "100%" and press the (+) and (-) buttons simul-
taneously. Internal checks are performed automatically,
and when each adjustment point is within a fixed range,
correction is performed and "SUCCESSFUL!" (figure at
the right) is displayed.
If an adjustment point is not within a fixed range, an error
is displayed (figure at the right) and the correction data
are not updated.
5 (To abort execution, press the (END) button.)
When ending adjustment, return to the initial screen by
pressing the (END) button 3 times.
Adjuster/ADJUSTER
is displayed (figure at the right) and the correction data is
not updated.
4 (To terminate execution, press the (END) button.)
When ending adjustment, return to the initial screen by
pressing the (END) button 3 times.